Laurel-electronics LT SERIES TRANSMITTERS ANALOG INPUT Manual do Utilizador Página 38

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 40
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 37
- 38 -
Over-voltage protection ....................................................................................................125 Vac
Open sensor indication ..............................................0 mA or > 20 mA output, jumper selectable
Type Range Conformity Error
J
-210 to 760°C
-347to 1400°F
0.09°C
0.16°F
K
-244 to 1372°C
-408to 2501°F
0.10°C
0.17°F
T
0 to 400°C
-257 to 0°C
32 to 752°F
-430 to 32°F
0.03°C
0.20°C
0.05°F
0.36°F
E
-240 to 1000°C
-400 to 1830°F
0.18°C
0.32°F
N
-245 to 1300°C
-410 to 2370°F
0.10°C
0.17°F
S
-46 to +68°C
-51 to +213°F
0.12°C
0.22°F
R
-45 to 1768°C
-49 to 3214°F
0.17°C
0.31°F
Resistance Input
Range Resolution Excitation Input Error
0-20.000

0-200.00
0-2000.0
0-20000
0-200.00 k
0-2.0000 M
Ω*
1 m
10 m
100 m
1
10
100
5 mA
500 µA
50 µA
5 µA
500 nA
500 nA
0.01% of range
± 2 counts
* Factory special fixed range
Load connection: .....................................................................................................2, 3 or 4 wire
Span tempco..............................................................................................±0.003% of reading/ºC
Over-voltage protection ....................................................................................................125 Vac
Open sensor indication ..............................................0 mA or > 20 mA output, jumper selectable
Vista de página 37
1 2 ... 33 34 35 36 37 38 39 40

Comentários a estes Manuais

Sem comentários